基于EDNR工艺的应用探讨生物脱氮所需碳源量
扶志远
(中麒水务科技(深圳)有限公司,深圳宝安)
摘 要:长期以来业内普遍认为城镇生活污水生物脱氮反硝化碳源与硝态氮的比值应在4以上,即:(BOD/N≥4),生物脱氮才能高效进行。通过EDNR工艺实际案例结合理论计算发现,生物脱氮所需的碳源量远小于传统脱氮工艺给出的经验值,多数城镇生活污水中的碳源量是充足的。实际工程案例发现,污水中可生物生物降解的需氧量(Available BOD,简称ABOD)远远大于实验室分析出来的BOD,实际案例的应用表明,可微生物降解的需氧量(ABOD),都可以在反硝化过程中作为碳源被利用。EDNR工艺的应用表明,对绝大多数的城市污水而言,无需外部投加碳源,出水TN可稳定在3mg/L以下。
关键词:生活污水 EDNR工艺 生物脱氮 可生物降解的需氧量(ABOD)
中图分类号:
Discussion on carbon source for biological nitrogen removal based on Application of EDNR process
FU Zhiyuan
(1.Zhongqi Funeng Water Technology Co.Ltd,Guangzhou510080)
Abstract:For a long time, it has been generally believed that the ratio of denitrification carbon source for should be more than 4, that is: (BOD / N ≥ 4), then biological nitrogen removal can be carried out effectively. In most cases, the amount of nitrogen removal is far less than that of the traditional process. The actual engineering case of ednr process shows that the available biological oxygen demand (ABOD) in the wastewater can meet the demand of denitrification for carbon source, and the effluent TN is stable below 3mg / L without external carbon source.
Key words:Domestic sewage EDNR process Biological denitrification Carbon source
近年来,国家对城镇污水处理厂总氮排放要求日益严格,多数城镇污水厂经过优化改造后,出水水质能够达到一级A标准,其中COD、BOD5和氨氮出水指标基本达到地表Ⅳ类水体要求,但是总氮较高,在10-15mg/L。目前城镇生活污水生物脱氮主要采用传统A/O脱氮工艺与深度脱氮相结合的方式。业内普遍认为污水中碳源量与总氮的比值应在4以上,即:(BOD/N≥4),生物脱氮才能进行,多数城镇生活污水碳氮比偏低,碳源不能满足脱氮要求,进而影响出水水质。这种观点使的污水厂在生物脱氮过程中往往依靠外部投加碳源的方式提高脱氮率,不仅增加了处理成本和能耗,还会出现碳源投加过量或不足的问题。因此,科学认识和利用污水中的碳源对水处理生物脱氮的发展具有重要意义。
-